    Diagnostics: Kits, Instruments , Clinical Chemistry Control reagents

Clinical Chemistry Control Reagents
calibration standards, reference standards, usp reference standards, clinical chemistry controls, hematology controls, diagnostic controls, toxicology controls
------------------------------------------------------------------------------------------------

Clinical Chemistry product line offers an array of critical raw materials (intermediates) and finished reagents to diagnostic manufacturers and clinical laboratories. ISO 9001 certified and manufactured in cGMP facilities.


Direct Amylase
Lipase Color
Liquid HDL
Liquid HDL Cholesterol Calibrator
HDL Linearity Verifiers
LDL Cholesterol Calibrator
LDL Linearity Verifiers
LDL
wrCRP

 

Direct Amylase

Product Overview:

Direct Amylase is a fully automated single liquid reagent for the measurement of Amylase in the clinical chemistry laboratory. Measurement of Amylase, in conjunction with Lipase, is used in the diagnosis of acute pancreatitis.

Key Assay Attributes:

Single liquid reagent with 2 year stability
Direct CNPG3 Substrate requiring no coupling enzymes
No lag phase
Linearity to 20 times the upper reference range

Top

Lipase Color

Product Overview:

Lipase Color is a fully automated colorimetric reagent for the measurement of lipase in the clinical chemistry laboratory. Measurement of lipase, in conjunction with Amylase, is used in the diagnosis of acute pancreatitis.

Key Assay Attributes:

Simple kinetic colorimetric assay requiring no sample blank
Specific for pancreatic lipase
No interference from pancreatic cholesterase, hepatic lipase or lipoprotein lipase
More accurate than turbidimetric
Linearity to 750 U/L

Top

Liquid HDL

Product Overview:

HDL is a liquid, two-reagent homogeneous method for the direct measurement of HDL cholesterol. The method is completely automated on most clinical chemistry analyzers, and does not require any off-line pretreatment, centrifugation or reagent reconstitution steps.

Key Assay Attributes:

Easy to use assay
Ready to use, stable liquid reagents with no reagent preparation
Works with fasting and non-fasting patient samples
Linear Between 3.7 and 200 mg/dL
No significant interference from elevated levels of ascorbic acid, bilirubin, hemoglobin, triglycerides or gamma-globulins
Calibrator traceable to the CDC reference method for cholesterol (NRS/Chol)
Precision exceeds the 1998 NCEP goals
Excellent correlation to the reference method
Performance exceeds the 1998 NCEP HDL cholesterol total error goals

Top

Liquid HDL Cholesterol Calibrator

Product Overview:

For the calibration of the Liquid HDL Cholesterol assay in serum or plasma.

Key Assay Attributes:

Unopened calibrator is stable at 2-8 degrees C until the expiration date printed on the vial
After reconstitution, calibrator is stable for 7 days at 2-8 degrees C
Reconstitution stability of the calibrator may be extended by aliquoting and freezing the reconstituted calibrator preparation at -20 degrees C or -70 degrees C for up to 4 weeks

Top

HDL Linearity Verifiers

Product Overview:

To perform linearity testing to verify the reportable range of the Liquid HDL Cholesterol assay.

Key Assay Attributes:

HDL Linearity Verifiers challenge the broad reportable range of HDL reagent
Results in fewer patient sample dilutions
Helps your laboratory gain efficiency through increased through-put
Improves turn around time
HDL Linearity Verifiers enable your laboratory to meet CLIA and regulatory requirements

Top

LDL Cholesterol Calibrator

Product Overview:

For the calibration of the LDL Cholesterol assay in serum or plasma.

Key Assay Attributes:

Unopened calibrator is stable at 2-8T C until the expiration date printed on the vial
After reconstitution, calibrator is stable for 2 weeks at 2-8T C
The reconstituted calibrator may be aliqoted and stored at -80T C

Top

LDL Linearity Verifiers

Product Overview:

To perform linearity testing to verify the reportable range of the LDL Cholesterol assay.

Key Assay Attributes:

LDL Linearity Verifiers challenge the broad reportable range of  LDL reagent
Results in fewer patient sample dilutions
Helps your laboratory gain efficiency through increased through-put
Improves turn around time
LDL Linearity Verifiers enable your laboratory to meet CLIA and regulatory requirements

Top

LDL

Product Overview:

LDL is a liquid, two reagent homogeneous method for the direct measurement of LDL cholesterol. The method is completely automated and applicable to most clinical chemistry analyzers, and does not require any off-line sample pretreatment, centrifugation or reagent reconstitution steps. As a fully automated reagent system LDL has revolutionized routine LDL cholesterol testing, enabling laboratories to realize significant operational benefits while at the same time improving the quality of LDL cholesterol results.

Key Assay Attributes:

Easy to use assay eliminates all sample pretreatment
Ready to use stable, liquid reagents with no reagent preparation
Works with fasting and non-fasting patient samples
Linear between 6.6 and 992 mg/dL
No interferences with triglycerides up to 1,200 mg/dL
Calibrator traceable to the CDC reference method for cholesterol (NRS/Chol)
Precision exceeds the 1998 NCEP goals for accuracy
Excellent correlation to the reference method
Performance exceeds the 1998 NCEP LDL cholesterol total error goals

Top

wrCRP

Product Overview:

wrCRP is an enhanced latex-agglutination turbidimetric immunoassay. Sample is added to the buffer solution and mixed with a suspension of mouse anti-human CRP monoclonal antibody that is bound to latex. CRP binds to the latex-bound antibody and agglutinates. The light scattering caused by the increase in particle size is used as a measure of CRP concentration. The amount of light scattering is proportional to the concentration of CRP in the sample.

Key Assay Attributes:

High Sensitivity - To measure very low concentrations.
Precision satisfies AHA and CDC recommendations for high sensitive method (CVs of <10% at levels of 0.3 mg/L to 10 mg/L CRP - A highly reproducible assay adds to the reliability of measurement.
Wide measurable range - To cover the clinically useful range with a single reagent.
No need for sample dilution up to 320 mg/L - Saves repeating a